Fanuc turret alarm reset manual. Feb 15, 2013 · We had the same problem.
Fanuc turret alarm reset manual Match the markings Press 'Call buzzer OFF' button. We have 19 Muratec manuals for free PDF download. Fordav11: The problem is that with our Fanuc lathe it is easy to hit the X+ limit due to the rather limited X-axis travel and when turning large workpieces with a tailstock it is just best to move the turret as far as possible before indexing (during manual set-up, quick tasks etc. If it's not a servo drive you might need to align the encoder by taking it off and align it. This manual mainly assumes that the FANUC SERVO MOTOR α i series of servo motor is used. The hydrics are full and everything else seems to work fine. I'm at a loss, any help would be appreciated. 2) i cant index the turret. 109 FORMA T ERROR IN G08 A value other than 0 or 1 was specified after P in the G08 code, or no 401 SERVO ALARM: (VRDY OFF) And I can't get rid of it, I push reset, it appears again, pull in/out EM STOP, alarm appears again. NG After looking in the manual there is no mention of an alarm 66, in fact the alarm appendix ends at AL-56. Mar 12, 2019 · I need some help, purchased a 1997 Miyano BND-42S2 with Fanuc OT-C and i am having turret issues. Fanuc 16 18-C Parameter Manual. PARAMETER OUT OF RANGE (TLAC) (M series) 5436. Electrically, the diagnostic page shows the turret unclamp solenoid high/energized output bit Y86. We'll cover everything from common causes to solutions, and provide a detailed list of potential alarm codes for easy reference. I hope someone here can guide me on the right direction troubleshooting this machine. I. Seems to me if it was a Fanuc drive, the alarm would be a Fanuc alarm instead of builder Feb 5, 2014 · The VDI live-tools of a Sauter-turret have a "lock" position. For servo motor and spindle information, refer to the manuals for the servo motor and spindle that are actually connected. The machine has two prox switches on the turret. It unclamps rotates and seems to get lost. 7 ARST Alarm Reset Emergency Button or Axes Emergency . You must first relieve the pressure from the servo. If this alarm has occurred, set the parameter PWE to 1 If this alarm has occurred, press <RESET> while pressing <PROG>, and only the program being edited will be deleted. Understanding Fanuc Alarm Codes # A. 0 & 300. I looked online and in the manuals I have but couldn't find the procedure. Repair manual says to rotate to pocket one and ref/index the turret, no help. Fanuc > Alarm EX1012 IN THE TOOL CHANGE AREA (Fanuc Robodrill ?-T21iFa) Deutsch Aug 19, 2004 · I unplugged the cable going to the turret after the index had finished and got a "T-Sensor" alarm. It's not an easy job and not one that I ever look forward to doing Mar 2, 2017 · You should have procedure for getting to Top Dead Center, in the operator's manual look for 'Preparing for Operation' or something like that. Nor do we know how to check the alarms on the diagnostics ladder. The above servo motors and the corresponding spindles can be connected to the CNC covered in this manual. Powered off and on. When I try it go's out and comes back in. Aug 30, 2021 · Use the list below to interpret what exactly the fault code is trying to communicate. Why Understanding Fanuc Alarm Codes is Crucial Page 1GE Fanuc Automation Sauter-Turret with nd 2 Geometry Tool Offset Data Function for 16i-TB, 18i-TB, 21i-TB ; Page 2GE Fanuc Automation This document shouldn’t be distributed to the end-user!! Document – Summery Title of Document Sauter-Turret and 2nd Geometry Tool Data Start of Edition: 02nd September 2002 Last Change: 28th January Jun 15, 2009 · appreciate all help & advice. We have restarted the machine and zeroreturned X and Z axis. 9 times out 10 it will pick up the station properly after this and continue on it's Before using the Robot, be sure to read the "FANUC Robot SAFETY HANDBOOK (B-80687EN)" and understand the content. Did check all wire and overtravel switch working find. Dec 21, 2002 · I have turret index trouble on a Hardinge conquest 51, 1993 model with Fanuc OT control. Nov 18, 2004 · Well, to find out if the turret is "normal" axis, but PLC controlled, look at any axis parameter - if there is one more to X&Z, then play with 1815 - when the turret is down, reset bit 4 to zero, power off/on, 1815. 5 V I think it's the Servo Amplifier Battery. Where to look next? Similar Threads: Need Help!-Fanuc 10tf, Axis Torque Alarm, mem Z axis Alarm, already changed Z drive and motor? alarm 408 servo alarm "serial not RDY", αP18 fanuc mtor code; Problem-Fanuc 6T-B alarm 402:servo Mar 12, 2019 · I need some help, purchased a 1997 Miyano BND-42S2 with Fanuc OT-C and i am having turret issues. Any ideas? Doosan Website alarm codes lookup brings up Dec 9, 2011 · This Alarm has come back, The servo control unit in the back of the machine has a display, it normally reads 0000 when all is working well. The turret was crashed into the chuck causing the machine to stop. Connections from the end of the turret wiring cable to micro switch are fine. No collisions or crashes involved. 2,find short point and remove it. That would point me in the right direction. Our '04 PUMA 240 MSB w/Fanuc 18iT control came up with an alarm this morning during normal operation : ALARM 2047:TURRET CLAMP SW. I would disconnect the wires that go from the Servo Drive to the motor first and see if the alarm 401 clears. 3 alarms, allowed me Our 1997 Akira Seiki turning center ASL-17 with a OT Fanuc control is alarming out with #1011 “Turret not ready”. Any help would be greatly appreciated!!! Similar Threads: Need Help!-Fanuc Robo Drill 14a 1012,1009 ALARMS OPERATION MANUAL - 6 - 30 - 1100 BAR FEED ALARM P. Anyone that have done the same fault i did and fixed it ? I have looked all over the manual, but can not find information to fix my problem. pump goes off, but if i hold the button in it stays on. APC Alarms Solution 300 APC Alarm DS030 Need Reference Nov 22, 2018 · 1: Press stand-by and reset for activating hydraulic pressure 2: Activate manually the valve for unlocking turret, making sure inductive position detector lights up. Install the turret tool plate and check that it is still aligned radially. If you require a replacement part, know that MRO Electric stocks thousands of FANUC CNC replacements. Cant reset or clear it. Make all 1's to clear tool clamp alarm and allow you to tool change to another tool. 5 change to a 1 Right to left 0 start Exec button Exit custom Turret +/- now clamp/unclamp the turret. The ‘Clamp open’ , ‘Tool change Switch’ & ‘X Block’ lights are on. Machine was turned off and then homed after turning back on. The export of Series 30 i/300i/300i s-MODEL A, Series 31 i /310 i /310 i s-MODEL A5 from Japan is subject to an export license by the government of Apr 12, 2011 · Nor do we know how to check the alarms on the diagnostics ladder. This alarm generates continuosly during home position(G28 U0 W0 in Auto cycle. OPERATIONAL DEVICES OPERATION B–63684EN/01 Table2. 2023 OPERATIONAL DEVICES 2. We could sure use some help. Mar 18, 2021 · That is a doosan alarm. Rebooting machine does however work clearing the alarm. Older machines use a hydraulic valve and geneva mechanism. 5" x 6" cover on front side top way in the back and below 2 sets of gears I happened to notice 2 sensors barely sticking out pointing to each one of the gear dogs. it keep give me the alarm 500 overtravel +x. Check the details on the alarm screen. When it try to index the other way, it spits out an alarm. Any sugestions. Go do D148. Apr 7, 2014 · fanuc series 18i-t problem is that i cant get to x zero return. Kind of think that turret home positions don't have to be reset on an incremental encoder. Jul 21, 2013 · The second is stated as an operator message but can be found in the alarm code section of the manual. I have been unable to clear the 1006 tool clamp alarm via the regular ES button and reset methods. May 15, 2013 · Fanuc 31i-a Doosan 2600sy alarm 2149 I was running a part that has been running all day. I'm facing one troubleshooting in yesterday was "Check Turret Station" alarm while go up X-axis Homing in CNC Lathe Machine. 3: Align turret dots by turning manually. HELP!!! May 11, 2013 · I then powered the machine down, hooked up the power cable, plugged the battery back in, and powered back on. Jun 12, 2019 · I tried turret restore procedure but get another Alarm OT0500 (Z)+ OVERTRAVEL (SOFT 1) during restore procedure. I couldn't find any batteries on the motors. Jul 6, 2004 · manual reference point return on a fanuc 0-m ? i need the procedure . Did everthing the manual said. :confused: Jan 7, 2016 · I am trying to start up a new to me 1995 Miyano BND34T2 and having issues. 4=1, power off/o, alarm 300 must disappear and it should go. i have to reset machine home axes. Jul 14, 2009 · I need the procedure for resetting the Turret from what I understand. So was hoping for some bright minds here. 6 DBC 130(F30i Series) DBC130ALE2A 1. 1 Ensure that the turret is at a safe location 2. Apr 29, 2013 · Newbe!! first time on the site. manual has this to say: "101 PLEASE CLEAR MEMORY The power turned off while rewriting the memory by program edit operation. Fanuc servo drive. When you rotate (unlock) a live-tool by hand it causes an alarm. How I did it was: I first adjusted param 1815 bit #4 to "0". Re: #2057 Turret Clamp Error(A9. I have been searching all over the net and the manuals today, And i cant seem to find a solution to reset the "2118 Turret Champ/Unclamp Alarm" i keep getting. It earlier did this without an alarm twice, it just stopped. Fuji drive and motor. (dots in my case but in some machines it's arrows, anyways it's easy to find) When the alarm is gone the display on the vision unit will read 0000. Manual solenoid valve release. The parameters are 105---106--- Feb 7, 2007 · I've just been fighting it severely for the last few hours to finish a handful of parts, faulting out on nearly every tool change, have to hit reset to stop it spinning, out of manual, calibrate the turret, reset to the right place in the program and continue. 2 EXPLANATION OF THE KEYBOARD Table2. Then hit the button in top left corner, which makes the turret to "lock" / "unlock". Main power keeps on. • No part of this manual may be reproduced in any form. Naturally there is no explanation of that alarm in the MTB's manual. After change of battery there is alarm #2062. The alarm comes up: NO. You can't change the toolnumbers in the software. After leaving the machine off for sometime, I get this alarm code. I can run the program just fine but when it comes to tool change, it can only index on way. I also can't figure out what retension knob fits this machine Apr 23, 2014 · Hi all, Our Hyundai Kia SKT210SY with a FANUC series 18i-TB control is having a problem with indexing the turret. :confused: PARAMETER MANUAL B-65280EN FANUC SERVO AMPLIFIER αi– B series DESCRIPTIONS B -65412 EN FANUC AC SERVO MOTOR αi series / FANUC AC SPINDLE MOTOR αi series / FANUC SERVO AMPLIFIER αi series MAINTENANCE MANUAL B-65285EN This manual mainly assumes that the FANUC SERVO MOTOR i series of servo motor is used. Initially Aug 7, 2012 · Good morning, sorry to disturb again but maybe I didn't describe problem in : We have lathe GA260 with system Fanuc 18 T and turret Sauter with 12 positions During last week we lost all parameters. Nov 9, 2009 · My problem now is that the Tornado 300 shows alarm message AL1018, and will not reset the alarm. Found the solution to this if you have a Fanuc Oi-TD with servo based turret. Controller is Fanuc OTC-F and the turret is Duplomatic Doosan Lynx 220 turning center Fanuc i control No. The turret never seats back, sets about ¼” out. 2 DI. Turned it back on and got an alarm 2062, AL 62 "Turret Amp Alarm". I tried to access the quick nc function but the machine will not respond to that either. i have a yama seiki lathe with a io-tc controal and when i turn it on today it came up with this: #2018 TURRET RUN ALARM (A4. K. Search "A0". Never had to reset home on one, and values in the APZ column read 0 (zero) when machine is working. They don't deal with what each builder wants to do as far as how the auxiliary devices are built, controlled, sensed, etc. 2047 Turret Clamp Switch Alarm or Turret Control Unit Alarm " Machine won't clear it. It has a Fanuc-P System 6M controller. Advertisement. 1 Press Reset, Press Estop 3. On my Doosan with 2 Sauter turrets; 1 I go through the whole turret reset method in the maintenance manual, though the method in the main part of the manual and the one in the back of the manual are slightly different. Control system is Fanuc 21i-TB. It's a Fanuc i Series control. Then adjusted K13 bit#0 to "1". • The appearance and specifications of this product are subject to change without notice. thx Similar Threads: Need Help!-Z + Overtravel alarm; Need Help!-FANUC OT ALARM 520 OVERTRAVEL +Z Dec 15, 2000 · (µ/ý XÄáêuÁCE@eÄÍ Ã0 Ã0€u ÃÞ2E¦îF’ Û)) …6I"‹=øË3[ŒZ‘j¤Åh5ª†þbÐw ømm½½¤‚Y«Â’bÇsár ' þ J B[·Æ¤NÌ©fÒ‡[à a( f Aug 19, 2016 · Is it a servo turret? You can reset the toolnumber by the small drive in the elektric cabinet. I know very little about this part. We checked the fuses to the best of our knowledge and tried to reset all the circut protectors. Does anyone know a solution to this alarm? machine. You will have to look for PMC parameters for turret servo. Still have the alarm and it wont turn manually. Not sure if yours is that way or not, but best to check your Doosan manuals for a battery change procedure. The X and Y axis will move in manual mode but no such luck for the Z axis. Now when I power up the machine I get a message (0612-13 machine not ready), the hydraulics power up and I can get into the parameters page but I can not move any of the axis. Now when the Alarm 2102 shows up on the control screen on the oprator panel, the Servo control in the back reads Pro-CE "the E has the top sagment missing tho". Anyway I reset it by using Parameter 1815. S: BAR FEEDER TYPE DH65 ALARM (D429=1) Alarm1100 Depending on bar feeder alarm message, refer to bar feeder manual to find solution Check if alarm message comes from barfeeder? END N Y Reset Reset Refer to electric manual, check the circuit relative to signal X12. I checked the function of the turret clamp Micro Switch, and it works fine. If an alarm is displayed, take appropriate action as explained in this manual. Similar Threads: doosan lynx 220c spindle rotation alarm no. Register the deleted program. I went through the procedure to reset the turret: Change keep relay #K5. When i try to reset as soon as i release the button the hyd. Jun 17, 2015 · My machine Nakamura TW10 18i-T Fanuc. You need to change the APZ to 0 first, before changing . s 414, 424, 434 on my alarm message screen. You will not get an alarm for the X axis, as it is set to 1. 2 2002 Spindle Alarm is Detected Mar 4, 2010 · There are three types of turret indexing on Miyanos. Page 18SAFETY PRECAUTIONS B-65395EN/01 1. Muratec CNC Turret Punch Press Programming Manual. Current issue: Machine Alarm Lamp is ON Only Diagnosis Alarms are: 300. I have Jan 8, 2007 · It doesn't stink, it just the way it has to be. There was 1 time i was able to hold the spindle stop button and turret index buttons to rehome the turret and hit reset button. Anyone with tips / ideas? Dec 28, 2015 · Have an older Hardinge Conquest 42 with a Fanuc 0TC system. Had the main board tested by Fanuc and they said it was O. Jan 12, 2006 · Doosan Lynx 220 Fanuc i Machine turret is in tool 00 position. the home position. Some daewoos and doosans used a non Fanuc servo drive for the turret. Mar 26, 2011 · First the FADAL ATC goes out and we spend almost two days tracing that down to bad wiring, now the Akira Seiki’s ATC is alarming and we are down again!(chair) Our 1997 Akira Seiki turning center ASL-17 with a OT Fanuc control is alarming out with #1011 “Turret not ready”. If the turret is not clamped check the relay as previously suggested. Steve Similar Threads: Need Help!-1011 alarm; Daewoo Puma 300 lathe turret alarm; Need Help!-FANUC-OM / re: Servo and turret adjust switch alarm messages; mazak laser 1011 mal11 alarm; Alarm 1011 Title: Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN/01 Author: KFAS Subject: GFZ-62755EN/01, Series 16/18/160/180-Model C Maintenance Manual Sep 11, 2013 · Hello firekoe, I captured to you my Fanuc 18i-TB Modules from the Machine (GoodWay Turning 2 Axis) The first Picture i found 2 battery locations number 1 and 2 but this is the factory default . We have 33 Fanuc 16 18 20 21 manuals for free PDF download. 2) Hi Bro, Please send email to help me fix Alarm #2057 Turret Clamp Error(A9. (Live tooling machines only) A lubrication alarm does not stop the machine, but will inhibit Cycle Start. How to install the app on iOS Follow along with the video below to see how to install our site as a web app on your home screen. If the work to be done requires that the door of the power mag Jan 28, 2009 · started taking the tool turret assembly off the machine to try and figure out the problem, pulled all the covers off the turret assembly again , this time the one 1. 2 . 2047 Turret Clamp Switch Alarm or Turret Control Unit Alarm Machine was shut off then turned back on and Homed. 2. Y 0 0 1 0 0 0 0 0 You will get the APZ alarm since it is at 0. Pls suggest how to escape from this thread. • Turret lubrication alarm message after 2000 hours of operation. Mar 24, 2010 · Only as information for future visitors, changing the batteries also removes the 1003 alarm Mis-Index (turret) in Feeler Ftc-280 machine With FANUC SERIES O-T system , Thank you for the tip!! 09-09-2013, 07:25 PM #9 Jan 18, 2014 · We having fanuc series oi-mate TD controle. Start scrolling through that area. When cycling the turret i get alarm 1024 — tool turret position monitoring. 2004 / TURRET ADJUST SWITCH ON (manual says: Tool change area detecting switch is reset) I was told the main servo amplifier board was bad, so $2k later I still have the same problem. Sep 28, 2017 · I turned it on, got the low battery alarm, waited a couple of minutes, turned it off, and replaced the battery. Oct 4, 2007 · After rebooting the machine, I can program a tool change and it will change to the correct tool, but then alarm out afterwards. Diagnostics #452 Turret adjust switch. And on servo amplifiers there is no alarm code, just " -" as not ready. PMM had all of the alarms and 11 bit 0 was 10000000. OPERATOR MESSAGE - NO. . A backup battery for absolute encoder for turret servo was dead. One is for Jul 11, 2007 · This may all be related to a soft thermal on the turret indexing motor (if the turret is indexed with a Fanuc Servo). Jan 16, 2009 · Our 1997 Akira Seiki turning center ASL-17 with a OT Fanuc control is alarming out with #1011 “Turret not ready”. Fanuc just makes the control hardware and software to control axis motion and I/O hardware. Did manually force the switch and check at PCDIagnosis bit did change 1 to 0 (on & off) X39. 3. Get your new FANUC servo amplifier or check out our FANUC servo motors. 1. For example, (13) means that the first and third power ; Page 1741. But we still have the 300 APC alarm about the 3 axis. Problem is that i did not get the correct manuals with the machine. Now i cannot lock it back into position, i do have a “Turret Unclamp” button but it doesnt work, not even in MDI or JOG mode. It includes all those buttons, plus releasing the turret, spinning it back around so the physical witness marks line up, locking the turret again, and changing the Jul 24, 2015 · OK, thank you everybody. Every time we indexed the turret, the turret would jump 2 tool stations. The machine is a 2006 Doosan 2000sy with a Fanuc 18i-TB control I have attcahed afew photo's Similar Threads: Fanuc 18i-TB Alarm 2102; Doosan 2000sy work ejection; Mastercam V9 or X3 Post for Doosan 2000sy; Doosan 2000sy; Doosan 2000sy not on center Sep 17, 2018 · Managed to reset the turret position accordingly and everything is working as it should (apart from an audible clunk when going either way past turret position 13? - everything else is near silent) Issue i'm having now is, randomly the position of the turret on the LCD display on the Fanuc control panel randomly changes during a program. Kind Regards Stefan P. 2. 1815 X 0 0 1 1 0 0 0 0 This is the way it should appear with no alarms. OR TURRET CONTROL UNIT ALARM We checked the TURRET CLAMP input signal X7. I think he thought the Fanuc controller was locked up for some reason so he shut down the machine and when he restarted this alarm was active. If we input T0202 it would jump to tool T0404 but the screen would show T0202. It's a Yama Seiki with Fanuc 0i-tc. Please send a clear procedure to recover the machine working? For general Mitsubishi servo turret reset please following the procedure hereunder. Try to follow the instruction given on the ELECTRICAL MANUAL for the alarm 1003, but the alarms stays on the machine without change. The machine alarm disappeared for about 5 minutes but while the machine was sitting idle it came right back. 1 Press & Hold Zero Return button, Press Turret Index Note: turret should index to station 1'' Best of luck So I have a DMC DL21 series lathe machine and while operation an operator pressed emergency when it was switching tools. Then ream the dowel holes and replace with new taper pins. Here's the alarm code and message: NO. I then went in and unclamped the turret, via Fanuc's re-zero procedure, manually rotated the turret back to tool #1 station, re-clamped, and then reset 11 to 10000001. 2 Caution CAUTION • Note whether an alarm status relative to the amplifier is displayed at power-up or during operation. The reset procedure should be in one of their manuals. #016 X axis home limit (Bit 5) #017 Y axis home limit (Bit 5) #018 Z axis home limit (Bit 5) #720 X axis alarm bits #721 Y axis alarm bits #722 Z axis alarm bits Jun 12, 2014 · Hey there. Apr 27, 2024 · There's a list of Fanuc Alarm codes below to help. You can find the manual online. Problem is a 1003 Alarm, “turret unclamp”. Dec 3, 2015 · Have an older Hardinge Conquest 42 with a Fanuc 0TC system. MANUAL INTERVENTION IN 3–D CIR (M series) 5435. B–63690EN/01 PREFACE p–1 This manual describes the specialized parameters for the following model: Product name Abbreviation FANUC Series 16 i–PB 16i–PB FANUC Series 18 i–PB 18i–PB SEIKI – SEICOS 10L 21L CNC Lathe Programming Manual SEIKI – SEICOS 10L 21L Vertical CNC Lathe Operating Manual Hitachi Seiki CS20 25 Specification SEIKI – SEICOS 21L DISPLAY AND OPERATION D Alarm screen If an alarm is issued during operation, the group number of the slave causing the alarm is indicated at the right end of the message field on the screen. The fans come on but the motor isn’t turning. Also after rebooting, I can press the manual index button, but the turret just rotates endlessly until I reset the machine. Powered back down. Or fixing it. This comprehensive guide will help you understand and troubleshoot Fanuc alarm codes related to servos, spindles, and TriStar CNCs. Nov 22, 2009 · appreciate all help & advice. It either indexes but is in the wrong position (half way between tools and locks into place), only releases and does not actually turn, or i get a servo alarm on the amplifier. I am missing the cnc operators manual that I am sure tells me what to do about this. I recently spent big bucks to have the controller/servo amplifier supposedly repaired because I was (and still am) getting a red "HC not ready" light on the unit as well as ALARM no. Rotate the disc by hand. 1 must be 1 for 12 position and K14 must be written No. 0 = 1 indicating the CLAMP switch input was correct. Problem: I lost my home position, still dont know how, from a shut down of two days this issue appear. I have tryed to turn it off and on for several times, but no progress. The products in this manual are controlled based on Japan's “Foreign Exchange and Maintenance manual states that it is a generic alarm. DISPLAY AND OPERATION B–63525EN/02 When five Apr 10, 2012 · the alarms will not reset, powering down will not get rid of them either. The problem showed up as a turret unclamped alarm after an index while setting up tools for a job. Fanuc just provides a tool (PMC) for the machine builder to write software (ladder program) to control whatever equipment the machine Nov 13, 2017 · 2006 / Hyunday-kia SKT 200 / Fanuc 0i-TC Hi everyone. + is unclamp - minus is clamp Unclamp the turret, select T in the hand wheel mode, jog the turret with the hand wheel to position 1. how do we zeroreturn the third axis? Similar Threads: Need Help!-DGN parameters Nakamura Tome TMC15M Fanuc OTC PMC-M how to enter PMC parameters? fanuc 11m parameters; Fanuc parameters; Fanuc 3T Parameters; Parameters Fanuc 6M Jun 3, 2006 · Hi guys, Got this 1998 emcoturn 325 running fanuc 21 - tb. " Sep 9, 2021 · Can you determine if the turret is actually clamped while the alarm is displayed? If the turret is clamped but the alarm is still issued you need to look in the ladder. The turret is also not locked, i can turn it around. Machine is not movable (nor in handle mode). 6 volt. Your Electrical (Victor) manual contains a chapter how to rotate the turret when above solution dosn't work. 0 to "1" Simultaneously press 'Spindle select' & 'Spindle stop' & 'Feed hold' Apr 30, 2009 · 2004 puma 240L fanuc 21i-TB we had the servo battery go bad 3. Has anyone have this problem and fix it? Sep 17, 2008 · Can anyone help. Rotate it till you feel the "lock" and replace it on the turret. Procedure is at initial power on, if TDC is not lit, select manual mode, set index pins IN, close workclamps, set press selection switch to 'Inching', then press and release 'Punching' button until TDC is Sep 25, 2017 · Turned it back on and got an alarm 2062, AL 62 "Turret Amp Alarm". Has any one see this alarm and if so how do i fix the problem. we replaced that yeserday ran the machine turned on and ran today for an hour then we got alarm 2023 (not locking in the 10 sec interval) then switches to alam 2047 (turret clamp switch alam or turret control unit alarm May 3, 2006 · These were used with Fanuc drillmate OMB and OMC models. I have a Takasawi TC-3 with an O-T control. ). I have a Hardinge Conquest T42 lathe the alarm will not reset. 0 to "1" Simultaneously press 'Spindle select' & 'Spindle stop' & 'Feed hold' Now turret will get unclamped. For α Jul 12, 2013 · Looking it up in the alarm code area of my manual it states: "TOOL CHANGE AREA DETECTING SWITCH IS RESET". Then powered off and just turned the turret by hand to correct position. I have the Fanuc manuals but not the manufacturer manuals. 2028 So I had to do turret positioning again. It somethin like "internal force signal" which cause this issue. 1) and #2018 Turret Run Alarm (A4. One describing how to reset the X-axis, one on resetting the Z-axis. Steve Similar Threads: Need Help!-1011 alarm; Daewoo Puma 300 lathe turret alarm; Need Help!-FANUC-OM / re: Servo and turret adjust switch alarm messages; mazak laser 1011 mal11 alarm; Alarm 1011 (Manually turret turn witout problem) Description in manual is -Reset number of position According manual we have to set keeprele K01. The maint. Servo motors driving the Turret. I just got my 1992 fanuc drillmate 10 T with 0M controll wired up and running. i try to do the P and CAN but my P is on the O key. 2 Explanation of the MDI keyboard Number Name Explanation 1 RESET key Press this key to reset the CNC, to cancel an alarm, etc. 1 Release Estop, Press Estop Reset 4. do i have to hold the SHIFT key too? or the P key is thing else that i dont know of. RESET 2 HELP key Press this button to use the help function when uncertain about the op ; Page 3802. 2066 AL-66 TURRET INDEX COND. replaced those it Jan 4, 2014 · Then you tap the turret around until it is aligned radially and then repeat the turret plate removal and tighten all of the bolts on the curvic. 0 - Main turret stop position Alarm 300. May 27, 2011 · We checked the 2 E stop switches and they are both reset. clamp the turret, and make sure it's clamped, it still has a coupling it locks in to. EDIT: Don't know if these procedures will work for incremental encoders. 1. Next, we inspected the ProMotion AC Servo Drive for the servo turret and found that it Manual (Alarm) (DBC 130/ R652. Mar 17, 2020 · If what drdos does not work, here are the turret reset instructions from the Hardinge OT manual ''1. 1) (CNC GA2600 Yama Seiki - Goodway) The products in this manual are controlled based on Japan’s “Foreign Exchange and Foreign Trade Law”. Got hold of this machine a few months back and it being shoot down and i have been spending much time cleaning it and troubleshooting alarms. 3 - Main turret position detection alarm I changed batteries, followed the Turret Re-Teach procedure which changed the Machine Alarm Lamp from ON to FLASHING, removed the 300. Alarm code: " No. Feb 24, 2013 · (µ/ý Xôá x DD@eÄÍ Ã0 Ã0€u ÃÞ2EÒ·%I„í””ˆB›$‘Å ž™g‹Q+ô£ŽãjT ýÅàÇ"úÛÚz{I ³V…UªQ — , N ˜Óͤ [÷Æ%ÊT¢ ^”®“V Aug 1, 2015 · OK, thank you everybody. I have problem with fanuc 15T system with "OT007 z+ overtravel (Hard) alarm" and cannot be RESET. Fanuc 16 18-C Machining Center Operator Manual. A few weeks ago i changed a turret encoder in a lynx220. Find quick tip videos for technical troubleshooting, issues, and part replacements on FANUC CNC Alarms, Servos, and batteries. After finishing a live tool cut on the sub spindle, the turret retracted to it's tool change position, and then alarmed out with "2149 servo drive overload alarm: check the overload states of turret. of tool position in binary code If Iam not wrong 12 positions = 00001100 There are T/D parameter also probably have to be set up, or something else. Feb 15, 2013 · We had the same problem. Ladder; Look at the PMC status bits. The machine alarm light is on, turret does one of a couple things. we never seen any batteries here before But I found a black case under the Fan unit it contains 4 batteries every one is 1. 3. Clear the alarm message as follows: If the machine is equipped with a Fanuc control, press the Feed Hold and Reset push but- tons at the same time to clear the alarm. rllu ezrtdov dgml byessqn xpbkkgl angtx hymts bczy krtd smni
Follow us
- Youtube